##TITLE= Audit trail, TopSpin 4.4.1
##JCAMPDX= 5.01
##ORIGIN= Bruker BioSpin GmbH & Co. KG
##OWNER= nmrsu
$$ /opt/topspin4.4.1/nmrdata05_09_2025/Basit/PTh-BOD-DCP(2)/76/pdata/1/auditp.txt
##AUDIT TRAIL=  $$ (NUMBER, WHEN, WHO, WHERE, PROCESS, VERSION, WHAT)
(   1,<2026-10-09T13:42:01.892+0000>,<nmrsu>,<localhost-nmr>,<go4>,<TopSpin 4.4.1>,
      <acquisition in progress>)
$$ /opt/topspin4.4.1/nmrdata05_09_2025/Basit/PTh-BOD-DCP(2)/76/audita.txt
(   2,<2026-10-09T13:44:29.882+0000>,<nmrsu>,<localhost-nmr>,<go4>,<TopSpin 4.4.1>,
      <created by zg on 'Avance' (localhost-nmr) by user 'nmrsu'
       on data set with UUID '34e2179c-c3e7-11f1-9e28-00139526ce8f'
       started at 2026-10-09 13:42:01.892 +0000, POWCHK enabled, PULCHK disabled,
       completed at 2026-10-09 13:44:29.878 +0000
       configuration hash MD5:
       4B D3 0E 61 81 EA 46 7E BC E1 2B 12 BC 91 2D AB
       double data hash MD5: 64K
       C4 66 D6 97 CC E7 8D 4D 77 73 1E 85 1F 13 F3 06>)
(   3,<2026-10-09T18:43:05.393+0500>,<nmrsu>,<localhost-nmr>,<xwish3>,<TopSpin 4.4.1>,
      <ICON-NMR User ID: Basit
       double data hash MD5: 64K
       C4 66 D6 97 CC E7 8D 4D 77 73 1E 85 1F 13 F3 06>)
(   4,<2026-10-09T18:43:06.478+0500>,<nmrsu>,<localhost-nmr>,<proc1d>,<TopSpin 4.4.1>,
      <Start of raw data processing
       ef LB = 0.3 FT_mod = 6 PKNL = 1 SI = 64K
       fid double data hash MD5: 64K
       C4 66 D6 97 CC E7 8D 4D 77 73 1E 85 1F 13 F3 06
       data hash MD5: 64K
       2A 6E F1 00 41 41 39 3D 27 4C 8F 72 13 D1 D4 57>)
$$ /opt/topspin4.4.1/nmrdata05_09_2025/Basit/PTh-BOD-DCP(2)/76/pdata/1/auditp.txt
(   5,<2026-10-09T18:43:07.874+0500>,<nmrsu>,<localhost-nmr>,<proc1d>,<TopSpin 4.4.1>,
      <apk0
       data hash MD5: 64K
       E9 AF 27 AA 67 75 75 8F 0E 1C EA 1A 0F CA FA 5E>)
(   6,<2026-10-09T18:43:07.898+0500>,<nmrsu>,<localhost-nmr>,<sref>,<TopSpin 4.4.1>,
      <sref
       data hash MD5: 64K
       E9 AF 27 AA 67 75 75 8F 0E 1C EA 1A 0F CA FA 5E>)
(   7,<2026-10-09T18:43:07.919+0500>,<nmrsu>,<localhost-nmr>,<proc1d>,<TopSpin 4.4.1>,
      <abs ABSG = 5
       data hash MD5: 64K
       2A 24 D8 7A 24 31 3B 74 C1 47 91 48 25 1C 4C CB>)
(   8,<2026-10-09T18:43:07.941+0500>,<nmrsu>,<localhost-nmr>,<peak>,<TopSpin 4.4.1>,
      <1D Peak picking
       data hash MD5: 64K
       2A 24 D8 7A 24 31 3B 74 C1 47 91 48 25 1C 4C CB>)
(   9,<2026-10-09T18:43:08.005+0500>,<nmrsu>,<localhost-nmr>,<xwish3>,<TopSpin 4.4.1>,
      <ICON-NMR User ID: Basit
       data hash MD5: 64K
       2A 24 D8 7A 24 31 3B 74 C1 47 91 48 25 1C 4C CB>)
##END=

$$ hash MD5
$$ 20 50 2E 06 CE 75 3B C6 D2 94 48 31 C5 91 A8 14